Free 3V0-21.21 Exam Braindumps

Pass your Advanced Design VMware vSphere 7.x exam with these free Questions and Answers

Page 5 of 18
QUESTION 16

An architect is reviewing a physical storage design. The customer has specified that a new active-passive based storage array will be used to provide storage for the vSphere clusters.
Which configuration should for the architect recommended?

  1. A. VMW_SATP_LOCAL
  2. B. VMW_PSP_MRU
  3. C. VMW_SATP_DEFAULT_AA
  4. D. VMW_PSP_FIXED

Correct Answer: B

QUESTION 17

Which requirement would be classified as a functional requirement within the design documentation?

  1. A. The system must perform virtual machine backups through an API.
  2. B. Virtual machines must be patched within one month of the patch release date.
  3. C. Virtual machines must be restarted within 30 minutes of a host failure.
  4. D. The system must be able to scale to support 500 concurrent virtual machines.

Correct Answer: C

QUESTION 18

An architect is designing a new vSphere environment with the following resources:
3V0-21.21 dumps exhibit 600 vCPU
3V0-21.21 dumps exhibit 5,760 GB RAM
Average resource usage is:
3V0-21.21 dumps exhibit 60 vCPU
3V0-21.21 dumps exhibit 1,152 GB RAM
The design must meet the following requirements:
3V0-21.21 dumps exhibit The environment has the ability to burst by 25%.
3V0-21.21 dumps exhibit Each host can schedule 36 vCPUs and has 512 GB RAM.
3V0-21.21 dumps exhibit Management overhead is 20%.
What is the minimum number of hosts required to meet the design requirements?

  1. A. Three
  2. B. Five
  3. C. Four
  4. D. Two

Correct Answer: D

QUESTION 19

Following a recent acquisition, an architect needs to merge IT assets into its current data center. The combined vSphere environment will need to run the newly acquired company’s virtual machines.
Network integration work has already been completed and the current environment has capacity to host all virtual machines. The Operations team needs to identify which virtual machines belong to the acquired company and report on their usage.
How should the architect merge the company’s assets and virtual machines?

  1. A. Leave the newly acquired company’s assets in its current place
  2. B. Lift and shift the acquired assets into the data center
  3. C. Migrate the acquired company’s virtual machines into the existing vSphere environment
  4. D. Migrate and apply vSphere tags to the acquired company’s virtual machines

Correct Answer: D

QUESTION 20

A customer defines a requirement to minimize the vMotion migration time during a maintenance period. The servers being used are equipped with eight 1 GbE network adapters.
Per the defined logical network configuration, there are two network adapters each used for:
3V0-21.21 dumps exhibit Management traffic
3V0-21.21 dumps exhibit vMotion traffic
3V0-21.21 dumps exhibit iSCSI traffic
3V0-21.21 dumps exhibit Virtual machine traffic
Which design decision should the architect make to meet the customer requirement?

  1. A. Use Network I/O Control to define a reservation for vMotion traffic.
  2. B. Implement Multi-NIC vMotion by adding additional vMotion VMkernels.
  3. C. Configure a dedicated TCP/IP stack for vMotion traffic.
  4. D. Combine vMotion and Management traffic to make use of four adapters.

Correct Answer: A

Page 5 of 18

Post your Comments and Discuss VMware 3V0-21.21 exam with other Community members: